After-sales Service: | Provide After-Sales Service Guarantee |
---|---|
Warranty: | 1 Year |
Nature of Source Flow: | Passive inverter |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AS Single Phase | 3600W | 6500W | |
Parallel mode (function reserved) | |||
Allow quantity | 1~6 | ||
Mains mode | |||
Nominal input voltage | 120Vac±5% | ||
Input phase voltage range | (90Vac~140Vac)±2% | ||
Frequency | 50Hz/60Hz(Auto detect) | ||
Frequency range | 47±0.3Hz~55±0.3Hz (50Hz); 57±0.3Hz~65±0.3Hz (60Hz); | ||
Max. efficiency | >95% | ||
Conversion time (bypass and inverter) | 10ms(Typical value) | ||
Max. bypass overload current | 40A | 60A | |
Inverter mode | |||
Output voltage waveform | Pure sine wave | ||
Nominal output power(VA)/(W) | 3600VA/3600W | 6500VA/6500W | |
Power factor | 1 | ||
Nominal output voltage (Vac) | 120Vac | ||
Output frequency range(Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | ||
Max. efficiency | >91% | ||
Overload protection | (102%<125%)±10%: 5 report error, turn off the output after minutes; (125%<150%)±10%: output after 10 seconds load>150%±10%: report error,turn off the output after 5 seconds | ||
Peak power | 7200VA | 12000VA |
Loaded motor capability | 2HP | 5HP | |
Nominal battery input voltage | 48V ( Min. start voltage 44V) | ||
Battery voltage range | 40.0Vdc~60Vdc±0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery... LCD screen can be set) | ||
Save power mode | Load≤25W | ||
Mains charge | |||
Battery type | Lead-acid or lithium batteries | ||
Max. charge current (configurable) | 40A | 120A | |
Charge voltage range | 40-60Vdc | ||
Solar charge | |||
Max. PV open circuit voltage | 300Vdc | ||
PV operate voltage range | 80-300Vdc | ||
MPPT voltage range | 90-260Vdc | ||
Battery voltage range | 40-60Vdc | ||
Max. PV input power/current | 4000W/22A | 4500W×2 / 22A×2 | |
Charge current range (configurable) | 0-80A | 0-150A | |
Max. hybrid charge current(PV+AC) | |||
Max. hybrid charge current (configurable) | 0-80A | 0-150A | |
Certification | |||
Safety certification | CE(IEC62109-1,2) | ||
EMC certification level | EN61000, C2 |
Operate temperature range | -15°C to 55°C | ||
Storage temperature range | -25°C ~ 60°C | ||
Humidity range | 5% to 95%(Three anti-paint protection) | ||
Noise | ≤60dB | ||
Cooling | Forced air cooling, adjustable wind speed | ||
Communicate | USB/RS485(/WiFi/GPRS)/Dry node control | ||
Dimensions(L*W*D) | 415mm*280mm*100mm | 540mm*350mm*120mm | |
Weight(kg) | 7.8 | 15 |