Customization: | Available |
---|---|
Nature of Source Flow: | Other |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Features
Technical parameters
Model |
NKD-8KW |
NKD-10KW |
NKD-15KW |
NKD-20KW |
|||
Rated Power |
8KW |
10KW |
15KW |
20KW |
|||
Battery
|
Rated Voltage |
96VDC/192VDC/220VDC/384VDC |
|||||
Voltage of over discharge protection |
86VDC/172VDC /194VDC/345VDC |
||||||
Controller
|
Rated Current |
100A |
|||||
Rated voltage |
96VDC/192VDC/220VDC/384VDC |
||||||
Number of inputs |
4 |
||||||
Max. current of each input |
25A |
||||||
Solar input voltage |
180VDC/<330VDC/<378VDC/<660VDC |
||||||
Voltage of overcharge protection |
115VDC/222VDC/255VDC/445VDC (programmable) |
||||||
Control accuracy |
±0.1 |
||||||
Display accuracy |
±0.1 |
||||||
Efficiency |
>95% |
||||||
Inverter
|
Input voltage |
110VAC±20%/220VAC±20% |
|||||
Input frequency |
50Hz/60Hz±5% |
||||||
Output voltage |
110VAC±2%/220VAC±2% |
||||||
Output frequency |
50/60Hz±0.01% |
||||||
Output waveform |
Pure sine wave, THD<4%(full load) |
||||||
Switching time from battey to mains |
<30ms |
||||||
Overload |
120% 20s; > 150%,10ms |
||||||
Efficiency |
≥90%(load power 100%) |
||||||
Dynamic Load Voltage Transients |
<±5%(0-100%) |
||||||
Protection function |
Output short circuit protection, over-voltage protection, under-voltage protection, low battery protection, etc. |
||||||
Automatic power on/off |
Light-operated power-on+fixed-time power-off (programmable) |
||||||
Other
|
Ambient temperature for operation |
-10~40ºC |
|||||
Relative humidity for operation/storage |
20-90%(no condensation, maximum) |
||||||
Dimension(mm) |
536*560*1015 |
635*566*1295 |
|||||
Weight(kg) |
180 |
200 |
240 |
257 |